Applicant | RAE Systems Inc – A Honeywell Company |
Address | 1349 Moffett Park Drive Sunnyvale, California 94089 United States of America |
Equipment | Portable combustible and toxic gas detector Models PGM62a0x, PGM62a6x and PGM62a8x |
Issue Number | 4 |
Issue Date | 2020-12-21 |
Status | Current |
Manufacturer | RAE Systems Inc - A Honeywell Company 1349 Moffett Park Drive Sunnyvale, California 94089 United States of America Additional Sites; RAE Systems (Shanghai) Inc. No. 990 E. Huiwang Road Jiading District Shanghai 201815 China Honeywell Sensing and Control (China) Co., Ltd. No.1668 Tianyin Road, Nanjing Science Park, Jiangning District, Nanjing, Jiangsu, 211100 China RAE Systems by Honeywell - A Honeywell Company 12220 Rojas Drive El Paso, Texas 79936 USA |
Protection Type | Intrinsic safety 'ia' |
Marking | With RAE LEL sensor Ex ia I Ma or Ex ia IIC T4 Ga -20°C < Tamb < +50°C With Dynament LEL sensor Ex ia I Ma or Ex ia d IIC T4 Gb -20°C < Tamb < +50°C |
Test Report | GB/SIR/ExTR11.0156/00, GB/SIR/ExTR11.0189/00, GB/SIR/ExTR12.0010/00, GB/SIR/ExTR12.0066/00 GB/SIR/ExTR12.0173/00, Sira AU/TSA/ExTR13.0042/00, TestSafe GB/SIR/ExTR14.0152/00, GB/SIR/ExTR17.0034/00, Sira |
Standards | IEC 60079-0:2011 IEC 60079-1:2007 IEC 60079-11:2011 IEC 60079-26:2006 |
Issued By | TestSafe Australia |
Notes |
There are no items in your cart.